Eco Clever
Show custom content to provide an overview of the image and heading
The Different Alarm Codes on the Eco Clever
What the different alarm codes mean and how to reset them
///
Difficulty level: Easy
Estimated time: 2 minutes
Eco Clever Alarm Codes
AL 1 - Black pad count has reached 250 cycles
AL 2 - Yellow pad count has reached 50 cycles
AL 3 - Green pad count has reached 50 cycles
AL 4 - Red pad count has reached 50 cycles
AL 5 - Compound count is reached
AL 6 - Water additive count is reached
AL 10 - Blu-Ray pad count has reached 150
AL 11 - Powered up with door open
AL 12 - Pad holder sensor
How to Reset Each One
Eco Clever Alarm Codes
AL 1 - 4
With the front door open. Press the corresponding number once. It’ll show the count for that stage. Press and hold the number again for around 5 seconds and it will reset that pad count
AL 5 + 6
With the front door open. Press number 5 once and it will show the compound count as ‘C’. Press and hold number 5 to reset this and then it shows the additive count ‘A’. Press and hold again and it will clear this count and show CD 0.
AL 10
With the front door open. To reset this you need to go into BR mode. To get there from CD mode press and hold the orange button until it’ll flash BD. Now press number 2 once and it’ll show 21 50. Now press and hold number 2 and it’ll reset this count and show BD. Press and hold the orange button again to show CD
AL 11
Simply close the main front door and switch the power off and back on again
AL 12
This means the sensor that gets a signal from the rear of the pad holder is not activating. This is most often due to dirt on the sensor or dirty pad holder. Clean both and try again.
Need Further Help?
If you have any further questions please don’t hesitate to contact the technical support team on 0800 4125 424 or by email at support@totaldiscrepair.co.uk