Eco Clever Alarm Codes

AL 1 - Black pad count has reached 250 cycles

AL 2 - Yellow pad count has reached 50 cycles

AL 3 - Green pad count has reached 50 cycles

AL 4 - Red pad count has reached 50 cycles

AL 5 - Compound count is reached

AL 6 - Water additive count is reached

AL 10 - Blu-Ray pad count has reached 150

AL 11 - Powered up with door open

AL 12 - Pad holder sensor 

How to Reset Each One

Eco Clever Alarm Codes

AL 1 - 4 

With the front door open. Press the corresponding number once. It’ll show the count for that stage. Press and hold the number again for around 5 seconds and it will reset that pad count

AL 5 + 6

With the front door open. Press number 5 once and it will show the compound count as ‘C’. Press and hold number 5 to reset this and then it shows the additive count ‘A’. Press and hold again and it will clear this count and show CD 0. 

AL 10

With the front door open. To reset this you need to go into BR mode. To get there from CD mode press and hold the orange button until  it’ll flash BD. Now press number 2 once and it’ll show 21 50. Now press and hold number 2 and it’ll reset this count and show BD. Press and hold the orange button again to show CD

AL 11

Simply close the main front door and switch the power off and back on again

AL 12 

This means the sensor that gets a signal from the rear of the pad holder is not activating. This is most often due to dirt on the sensor or  dirty pad holder. Clean both and try again.